Pre-registration to the ILC: HU-X-PC Determination of resistance to humidity of a paint coating (in cabinet)

HU-X-PC

Reference of the ILC

HU-X-PC

References of test methods

ISO 6270-2  ISO 2808  ASTM B659  ASTM D1186  ISO 2813
ASTM D523  ISO 7724 Parts 1, 2 & 3  ISO 11664 Parts 1 & 4
ASTM E308  ISO 2409  ASTM D3359 Met. B  ISO 4628 Parts 1 to 8
ASTM D610  ASTM D714  ASTM D1654

       

Frequency

For this ILC, there is a risk that the number of registrations is low. To ensure an enough number participants, a pre-registration procedure is put in place, as follows:

 

1 - Participants interested in participating pre-register using the registration form. No invoicing is made for this pre-registration;

2 - When at least 10 potential participants have pre-registered, CompaLab asks each of these pre-registrees to confirm their willingness to participate and what are the characteristics for which they commit to provide results;

3 - If at least 8 participants confirm their intention to participate, the CIL organisation concerned is engaged.

Main characteristics

AHT cycle (Condensation atmosphere with alternating humidity and air temperature) - Selected exposure times for assessment: 0, 3, 9 and 28 cycles of 24h - Rating of defects due to ageing in accordance with ISO

 

4628-2 and -3 - Cross-test against ISO 2409 after 28 cycles of 24h

Other characteristics

t (thickness of coating) in accordance with ISO 2808, Rating of defects due to ageing in accordance with ISO 4628-4 and 5, Gloss coefficients G20, G60, G85 in accordance with ISO 2813, Colorimetric parameters

 

L*-a*-b* in accordance with ISO 7724-1 to 3

 

Caution The number of determinations may be low for the secundary characteristics, what may make inefficient the comparison between laboratories

       

Format of the test results:

Results of some properties are numerical and some are expressed as a choice between several possibilities (categories).

 

 

Determination of the assigned values (“true values” for each characteristic)

By statistical computation of the totality of the results with possible selection on competence criteria (accreditation, validation by a reference body, quantity of tests performed in the year), test to detect possible collusion, merging of results not obtained in reproductibility conditions, suppression of technically unvalid results.

Type of statistical computation

For numerical results, the statistical computation will provide an assigned value with its attached uncertainty, values of standard deviations for repeatability and reproductibility, limits of alerts for bias and repeatability of the participant, indiviual values for uncertainty of results of participants.

 

For results expressed as a choice between several possibilities (categories), Gower indexes are computed from the results, which enables the calculation of assigned values, repeatability and reproducibility standard deviations, limits of alerts for bias and repeatability of the participant, indiviual values for uncertainty of results of participants.

Number of products submitted to tests

1

Number of samples per participation

6

Max number of operators per participation

1 (it is necessary to order as many participations as there are participating test operators)

Product submitted to tests

Paint coated steel

Type of samples

Plates

Approximate dimensions of samples

150x100x1 mm

Specific preparation to be performed by the participant

Protection of edges

                   

Special notice for this ILC

The samples are provided with a scribe against ISO 17872

   

Price (€)

425

Price if online payment (€)

340

Approximate weight (kg)

2

0,00€ excl. tax - 0,00€ inc. tax