FA25RS: Fatigue test of a concrete reinforcing steel
FA25RS
340,00€ excl. tax - 408,00€ inc. tax
Presentation for participants
FA25RS |
|||||||||||
References of test methods |
ISO 15630-1 |
||||||||||
Frequency |
Each year |
||||||||||
Main characteristics |
N (Number of cycles before failure for a given σmax and a given Δσ) |
||||||||||
Determination of the assigned values (“true values” for each characteristic) |
By statistical computation of the totality of the results with possible selection on competence criteria (accreditation, validation by a reference body, quantity of tests performed in the year), test to detect possible collusion, merging of results not obtained in reproductibility conditions, suppression of technically unvalid results. |
||||||||||
Type of statistical computation |
For numerical results, the statistical computation will provide an assigned value with its attached uncertainty, values of standard deviations for repeatability and reproductibility, limits of alerts for bias and repeatability of the participant, indiviual values for uncertainty of results of participants. |
||||||||||
Number of products submitted to tests |
1 |
||||||||||
Number of samples per participation |
5 |
||||||||||
Max number of operators per participation |
1 (it is necessary to order as many participations as there are participating test operators) |
||||||||||
Product submitted to tests |
Hot rolled reinforcing steel |
||||||||||
Type of samples |
Bars |
||||||||||
Approximate dimensions of samples |
2x Ø16-25x780 mm |
||||||||||
Specific preparation to be performed by the participant |
None (other than possible necessity to polish the test specimens or to adapt their dimensions to the equipment of the participant) |
||||||||||
Special notice for this ILC |
Results have to be numerical in order to be statistically handable. The number of samples is set up at 9, in order to make the estimation of standard deviation of results statistically relevant. So, to avoid tests to last too long and avoid costs of tests too high: |
||||||||||
Time schedule: |
|||||||||||
Opening date of registrations |
20/12/2024 |
||||||||||
Registration deadline |
15/03/2025 |
||||||||||
Date of shipment of samples |
30/05/2025 |
||||||||||
Start of the tests |
03/09/2025 |
||||||||||
Deadline for carrying out the tests and providing the results |
27/10/2025 |
||||||||||
Date of delivery of reports |
06/12/2025 |
||||||||||
Note: After the deadline, registrations are still possible. Contact us at ilc@compalab.org for more information. |
|||||||||||
Price (€) |
425 |
||||||||||
Price if online payment (€) |
340 |
||||||||||
Approximate weight (kg) |
20 |