GE-X-WJ: Participation to ILC Geometry of welded joint

GE-WJ

0,00€ excl. tax - 0,00€ inc. tax

Presentation for participants

Reference of the ILC

GE-X-WJ

References of test methods

ISO 6520-1  ISO 5817

       

Frequency

For this ILC, there is a risk that the number of registrations is low. To ensure an enough number participants, a pre-registration procedure is put in place, as follows:

 

1 - Participants interested in participating pre-register using the registration form. No invoicing is made for this pre-registration;

2 - When at least 10 potential participants have pre-registered, CompaLab asks each of these pre-registrees to confirm their willingness to participate and what are the characteristics for which they commit to provide results;

3 - If at least 8 participants confirm their intention to participate, the CIL organisation concerned is engaged.

Main characteristics

Cotation against ISO 5817 of transverse defects as defined in ISO 6520-1 (12 pictures provided)

       

Format of the test results:

For results expressed as a choice between several possibilities (categories), Gower indexes are computed from the results, which enables the calculation of assigned values, repeatability and reproducibility standard deviations, limits of alerts for bias and repeatability of the participant, indiviual values for uncertainty of results of participants.

 

 

Determination of the assigned values (“true values” for each characteristic)

By statistical computation of the totality of the results with possible selection on competence criteria (accreditation, validation by a reference body, quantity of tests performed in the year), test to detect possible collusion, merging of results not obtained in reproductibility conditions, suppression of technically unvalid results.

Type of statistical computation

For results expressed as a choice between several possibilities (categories), Gower indexes are computed from the results, which enables the calculation of assigned values, repeatability and reproducibility standard deviations, limits of alerts for bias and repeatability of the participant, indiviual values for uncertainty of results of participants.

Number of products submitted to tests

1

Number of samples per participation

12

Max number of operators per participation

10 (For this ILC, the type of test and sample size allow to provide results determined by several different operators and by several different methods)

Product submitted to tests

Pictures of welded joints

Type of samples

Document

Approximate dimensions of samples

-

Specific preparation to be performed by the participant

None (other than possible necessity to polish the test specimens or to adapt their dimensions to the equipment of the participant)

   

Price (€)

425

Price if online payment (€)

340

Approximate weight (kg)

0