Pre-registration to the ILC: TA-X-WJ- Transverse tensile test on welded joints

TA-WJ

Reference of the ILC TA-X-WJ
References of test methods ISO 4136
Frequency For this ILC, there is a risk that the number of registrations is low. To ensure an enough number participants, a pre-registration procedure is put in place, as follows:
  1 - Participants interested in participating pre-register using the registration form. No invoicing is made for this pre-registration;
2 - When at least 10 potential participants have pre-registered, CompaLab asks each of these pre-registrees to confirm their willingness to participate and what are the characteristics for which they commit to provide results;
3 - If at least 8 participants confirm their intention to participate, the CIL organisation concerned is engaged.
Main characteristics Rm, Location of fracture
Determination of the assigned values (“true values” for each characteristic) By statistical computation of the totality of the results with possible selection on competence criteria (accreditation, validation by a reference body, quantity of tests performed in the year), test to detect possible collusion, merging of results not obtained in reproductibility conditions, suppression of technically unvalid results.
Type of statistical computation For numerical results, the statistical computation will provide an assigned value with its attached uncertainty, values of standard deviations for repeatability and reproductibility, limits of alerts for bias and repeatability of the participant, indiviual values for uncertainty of results of participants.
Number of products submitted to tests 1
Number of samples per participation 6
Max number of operators per participation 1 (it is necessary to order as many participations as there are participating test operators)
Product submitted to tests Welded joints
Type of samples Plates
Approximate dimensions of samples 300x45x4-10 mm
Specific preparation to be performed by the participant  Machining of test specimens
Special notice for this ILC The test for this ILC is to be carried out without heat treatment. To assess separately the performance of heat treatments, another ILC with one series of samples to be tested  after a heat treatment of 1h at 600°C is organised by CompaLab, see: TH23WJ.
Price (€) 350
Price if online payment (€) 280
Approximate weight (kg) 5

0,00€ excl. tax - 0,00€ inc. tax

Reference of the ILC

TA23WJ

References of test methods

ISO 4136

       

Frequency

This ILC can be organised this year thanks to our preregistration procedure, which ensures an enough number of participants.

Main characteristics

Rm, Location of fracture

       

Determination of the assigned values (“true values” for each characteristic)

By statistical computation of the totality of the results with possible selection on competence criteria (accreditation, validation by a reference body, quantity of tests performed in the year), test to detect possible collusion, merging of results not obtained in reproductibility conditions, suppression of technically unvalid results.

Type of statistical computation

For numerical results, the statistical computation will provide an assigned value with its attached uncertainty, values of standard deviations for repeatability and reproductibility, limits of alerts for bias and repeatability of the participant, indiviual values for uncertainty of results of participants.

Number of products submitted to tests

1

Number of samples per participation

6

Max number of operators per participation

1 (it is necessary to order as many participations as there are participating test operators)

Product submitted to tests

Welded joints

Type of samples

Plates

Approximate dimensions of samples

300x45x4-10 mm

Specific preparation to be performed by the participant

Machining of test specimens

                   

Special notice for this ILC

To assess separately the performance of heat treatments, 2 series of 6 samples are provided: one series to be tensile tested without heat treatment and one series to be tensile tested after a heat treatment of 1h at 600°C.

   

Time schedule:

 

Opening date of registrations

30/11/2022

Registration deadline

30/06/2023

Date of shipment of samples

05/09/2023

Start of the tests

15/09/2023

Deadline for carrying out the tests and providing the results

31/10/2023

Date of delivery of reports

15/12/2023

Note: After the deadline, registrations are still possible. Contact us at ilc@compalab.org for more information.

                       

Price (€)

350

Price if online payment (€)

280

Approximate weight (kg)

5